『Specify vortex flowmeter』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. What is the accuracy level of vortex flowmeters according to national standards?
The accuracy level of vortex flowmeters in the tracking range follows national standards such as GB/T 32201-201
5, JJG 1029-2007, etc., and is classified according to the maximum relative error. Shen Luan Industry commonly uses levels below 1.0. 1. According to Chinas specifications for vortex flowmeters, the main national standards include: • GB/T 32201-2015 (Verification Regulations for Gas Flowmeters) • JJG 1029-2007 (Special Verification Regulations for Vortex Flowmeters) • JB/T 9249 (Technical Specification for Sensors in the Mechanical Industry) Precision level classification is determined based on the maximum relative percentage error, and the system is divided into three categories: - Level 1 standard: 0.00
5, 0.0
2, 0.05 (laboratory level) - Level 2 standard: 0.
1, 0.
2, 0.3
5, 0.5 (process detection level) - Industrial application
1.0, 1.
5, 2.
5, State Circle 4.0 (conventional working condition level) 3 Error control requirements take the commonly used 1.0 level instrument in industry as an example: - Allow a deviation of ± 2% below the boundary flow point - Limit the deviation above the boundary flow point to within ± 1%. Higher level 0.5 level instruments need to control an error of ± 0.25% in the range of 20% -100%
4. Core quality control indicators - repeatability error should be ≤ 1/3 of the maximum allowable deviation - Dynamic compensation requirements: viscosity fluctuation ± 20%, deviation ≤ ± 0.15%, temperature coefficient ± 0.01% FS/℃, pressure compensation accuracy ± 0.005% FS/kPa
2. Flow range of vortex flowmeter