『Quality flow meter setting』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. Compact Thermal Mass Flow Meter Installation and Setting Guide
Compact Thermal Mass Flow Meter Installation and Setting Guide
1. Installation Precautions Flow Direction: When installing a flowmeter, be sure to observe the arrow indicating the flow direction on the housing to ensure that the flow direction of air/gas is consistent with the arrow on the housing. This is the foundation for ensuring accurate measurement of flow meters. Requirements for straight pipe section: Although the flowmeter is integrated with a flow regulator and does not require an additional straight pipe section, in order to achieve the best measurement effect, it is recommended to use 3-5 times the inner diameter of the fiber large straight pipe at the inlet. Installation position: The flowmeter can be installed on horizontal or vertical pipelines, and the specific installation position should be determined according to the actual working conditions and pipeline layout. Process connection: For DN
8, DN1
5, DN20, DN25, and DN32 pipelines, G internal thread connection is used. Ensure that the connection is well sealed to prevent gas leakage.
Secondly, the electrical connection flowmeter is equipped with two wiring plugs "A" and "B". By default, it comes with a 5-meter cable with an M8 female connector on one end and an open wire on the other end. For flow meters, a single connecting wire can make them work properly. If it is necessary to separate the output pulse or the power supply and signal separately, two connecting wires need to be ordered.
3. Relevant Settings Download APP: After normal installation and wiring, a dedicated APP needs to be downloaded (Android phones can click on the download link, I